OPTIFLUX 4400

Electromagnetic flowmeter for safety instrumented systems (SIS) and high-accuracy requirements

  • Certified for safety applications up to SIL 2/3, with automated partial proof test capability for extended proof test intervals
  • Best-in-class diagnostic test interval incl. fault response time of only 2 minutes
  • SIL 2/3 up to DN600 / 24"; non-SIL up to DN2000 / 80" (larger on request)
  • Pulse, frequency, status, 4…20 mA, HART®7

OPTIFLUX 4400

Electromagnetic flowmeter for safety instrumented systems (SIS) and high-accuracy requirements

  • Certified for safety applications up to SIL 2/3, with automated partial proof test capability for extended proof test intervals
  • Best-in-class diagnostic test interval incl. fault response time of only 2 minutes
  • SIL 2/3 up to DN600 / 24"; non-SIL up to DN2000 / 80" (larger on request)
  • Pulse, frequency, status, 4…20 mA, HART®7

Overview

The OPTIFLUX 4400 electromagnetic flowmeter (EMF) is developed in accordance with IEC 61508 for safety-related applications up to safety integrity level (SIL) 2/3. It features automated partial proof testing capabilities, which allows to extend the time interval between full proof tests and increase plant uptime in safety instrumented systems (SIS).

  • Automated partial proof testing capability for extended full proof test intervals
  • Integrated conductivity measurement
  • Enhanced diagnostic package:
    • Compliant with NAMUR NE 107
    • Diagnostic test interval incl. fault response time of only 2 minutes: alert issued if meter runs out of spec
    • Detects gas bubbles, solids, electrode corrosion and deposits on the electrodes, conductivity changes, an empty or partially filled pipe, a disturbed flow profile, external magnetic fields, etc.
    • Redundant data storage
    • Real-time clock for logging events
    • User-friendly coloured display for status indication
  • Ease of installation and device set-up:
    • Optimised device menu: reduced menu items for quick commissioning
    • Available with patented "virtual reference" option: cost-saving installation without grounding rings (in non-SIL applications)
  • High measuring accuracy and long-term stability: measuring error of only ±0.2% of measured value ±1 mm/s
  • Wide range of liner and electrode materials
  • Approved for use in hazardous areas: ATEX, IECEx db eb
  • Field device verification of flowmeter with the OPTICHECK Master and OPTICHECK DTM service tools, e.g. for partial proof test documentation acc. to IEC 61508
Related products
0 / 0
IFC 400
Electromagnetic flow converter for combination with OPTIFLUX 4000 electromagentic flow sensor
  • SIL2/3 certified for use in safety integrated systems (SIS)
  • Compact, remote field, wall-mounted and rack-mounted housing
  • With extensive diagnostics for advanced requirements (NE 107)
  • 4-wire, pulse, status, frequency, 3 x 4…20 mA, HART®7
OPTIFLUX 4000
Electromagnetic flow sensor for combination with IFC 050, IFC 100, IFC 300 and IFC 400 signal converters
  • Full bore design: pipe cross-section without restrictions
  • Connection sizes: DN2.5…3000 / ⅒…120" (depending on signal converter)
  • Liner: PTFE, PFA, ETFE, PU, hard and soft rubber
Email